Features
TELEFIRE LON-3000 Network Communication Module
Create a unified, integrated fire alarm network with the Telefire LON-3000 communication module. This expansion card is designed specifically for networking Telefire ADR-3000 analog addressable control panels, allowing the interconnection of up to 32 control panels into a single, large-scale system. Through the module, panels communicate on a peer-to-peer basis, sharing information and controls, enabling full system monitoring from any point in the network.
The LON-3000 offers exceptional flexibility during installation, supporting bus, star, ring, and mixed topologies. The module utilizes LonWorks technology for reliable data transmission over twisted pair wiring. The networked system operates as a single integrated unit: it enables shared controls, conditional activation matrices (cross-zoning) between devices of different panels, and centralized monitoring. Using this module significantly expands system capacity and the number of monitorable addresses. In addition to galvanic connections, fiber optic networking is also possible using supplementary adapters (LRW-702/LR-01).
Key Features and Benefits:
- Network Integration: Connects up to 32 ADR-3000 fire alarm control panels into a single system.
- Flexible Topology: Supports bus, star, ring, and mixed network layouts to adapt to building infrastructure.
- Shared Control: Enables event signaling (fire, fault) and control activation (e.g., sounders, relays) across any panels in the network (global matrices).
- Expanded Capacity: usage allows for the expansion of the system’s addressable capacity (up to 508 addresses per panel context within the network).
- Simple Installation: The module connects directly to the control panel’s main board (J1 LON-COM connector), requiring no separate mounting or external power.
- Redundancy Option: In ring topology, communication is maintained even in the event of a single line break (bidirectional path).
- Low Power Consumption: Maximum current draw is only 31 mA.
Technical Specifications:
- Dimensions: 62 x 105 mm
- Weight: 50 g
- Operating Temperature: -10°C … +60°C
- Current Consumption: 31 mA
- Compatibility: Telefire ADR-3000 (software version 3.02Q or newer)
- Connections: J1 (main board interface), J2 (network terminal 1A-1B)
Related products
TELEFIRE BOX-7000B2
Metal Back Box for 7000 Series Control Panels
TELEFIRE BOX-7000B2
Metal Back Box for 7000 Series Control Panels
TELEFIRE BCF-10326
Smoke Release System
TELEFIRE BCF-10326
Smoke Release System
TELEFIRE ADR-823
Three-Channel Input/Output Module
TELEFIRE ADR-823
Three-Channel Input/Output Module
TELEFIRE ADR-818
Eight-Channel Input Module
TELEFIRE ADR-818
Eight-Channel Input Module