Features
TELEFIRE ADR-7001EM1 – Loop Expansion Card
The Telefire ADR-7001EM1 is a dedicated expansion module (subassembly) designed exclusively to increase the capacity of ADR-7000 analog addressable fire alarm control panels. This unit enables the system to manage additional addressable loops, making the control panel suitable for protecting larger and more complex facilities.
The card integrates seamlessly into the control panel’s internal architecture, ensuring reliable communication between the central unit and field devices (detectors, modules, notification appliances).
Key Features and Benefits
- Capacity Expansion: Allows the ADR-7000 control panel to handle additional detector loops, thereby increasing the area coverage and the number of supported devices.
- Ease of Installation and Maintenance: The card design is optimized for installers. Connectors are logically grouped: data and power inputs from the main board are located on the left side, while loop wiring connection points are positioned at the bottom.
- Full Integration: The module communicates directly with the ADR-7000 central unit, ensuring real-time data transmission and unified system supervision.
- System Security: Using the expansion card maintains system integrity and reliability in compliance with UL and EN standards.
Technical Specifications
- Product Code: ADR-7001EM1
- Type: Loop Expansion Subassembly
- Compatibility: Exclusively with ADR-7000 series fire alarm control panels
- Certification: UL 864 10th Edition (Control Unit Accessories, System)
- Connection: Internal system bus and terminal blocks for loop wiring
- Application: Fire alarm system expansion
Installation
During installation, the card must be mounted inside the ADR-7000 control panel housing on the appropriate mounting points. Wiring is facilitated by logically arranged connector groups, minimizing the risk of connection errors. Installation should only be performed by qualified personnel after powering down the system.
Related products
TSA-240
Conventional 4-Zone Extinguishing Control Panel
TSA-240
Conventional 4-Zone Extinguishing Control Panel
TSA-200
Two zone fire alarm control panel
TSA-200
Two zone fire alarm control panel
TPB-10G
Green manual push button designed to deactivate control for controlled doors during a fire / emergency event (single operation)
TPB-10G
Green manual push button designed to deactivate control for controlled doors during a fire / emergency event (single operation)
TFU-500
Flame Detector DRD-E
TFU-500
Flame Detector DRD-E